![]() ![]() Fill soils that support footings and foundations shall beĭesigned, installed and tested in accordance with acceptedĮngineering practice. R301 and of transmitting the resulting loads to the supporting Foundation construction shall beĬapable of accommodating all loads according to Section ![]() I hadn't thought of the bolt embedment as a way to provide a specific code section for interior slab/footing thickness.but I like it. How do you get an anchor bolt to extend 7 inches into the concrete if you do not have a footing? Remember the J-Bolt should be a minimum 3 inches from the earth just like the rebar. Hilti North America expanded its concrete anchor portfolio with the Kwik Bolt-TZ2, an easy-to-install high-performing. Bolts shall be at least 1/2 inch (12.7 mm) in diameter and shall extend a minimum of 7 inches (178 mm) into concrete or grouted cells of. Wood sole plates at all exterior walls on monolithic slabs, wood sole plates of braced wall panels at building interiors on monolithic slabs and all wood sill plates shall be anchored to the foundation with anchor bolts spaced a maximum of 6 feet (1829 mm) on center. Sill plates and walls supported directly on continuous foundations shall be anchored to the foundation in accordance with this section. In Seismic Design Categories D0, D1 and D2, interior footings supporting bearing or bracing walls and cast monolithically with a slab on grade shall extend to a depth of not less than 12 inches (305 mm) below the top of the slab. ![]()